Home » » Hospital Equipment » Infant Incubator

Infant Incubator

The infant incubator from Medcare, isolette, neonatal incubator or baby incubator as it is also known, is designed for the specific needs of infant nurseries and neonatal intensive-care unit (NICU), providing the safest and most stable environment possible for the critical newborn infants. It incorporates state-of-the-art technology, innovative design, and exceptional thermal performance to facilitate the outcomes of your newborn patients.

Features of the Infant Incubator
1. Microprocessor based servo controlled temperature system;
2. Air temperature, skin temperature, humidity, timer and heating power are displayed by LED separately;
3. Alarms functions for power failure, over temperature, temperature deviation, temperature sensor failure and fan failure;
4. Silence/reset button for alarms;
5. Integral timer for therapy time recording;
6. Humidity can be adjusted continuously;
7. >37℃ temperature setting;
8. A keypad lock on the infant incubator prevents change of setting caused by your carelessness;
9. Trough that can be pulled and pushed is designed for convenient adding of water;
10. Low noise fan with high longevity;
11. Through the front control panel, temperature deviation and over temperature can be amended directly;
12. The hospital incubator is designed with a second thermal cut-off function for more safety;
13. A protection function for skin temperature sensor failure can avoid over temperature;
14. The infant bed inclination angle is adjustable;
15. It comes with six operating windows, and the operating windows at two sides can be swiveled
16. Heater will be electrically cut-out if air temperature inside the incubator is more than 40℃
17. Big storage cabinet

Standard Configuration
Main body (including the transparent hood, control system, infant bed, water trough), skin temperature sensor, IV pole, mattress, cabinet, castors

Optional parts
Phototherapy unit: Providing phototherapy to infants from up and down sides
RS232 (485) connector;
Tray/pole

Technical Specifications
Power supply AC 110/220V 60/50Hz
Power input ≤420VA
Operating conditions Environment temperature 20℃ ~30℃
Environment relative humidity 30%~75%RH
Environment air velocity of flow <0.3m/s
Air temperature control range 25℃ ~38℃
Skin temperature control range 32℃ ~38.5℃
Skin temperature sensor accuracy +/-0.3℃
Temperature fluctuation +0.5℃
Uniformity of mattress temperature ≤0.8℃
Warm-up time ≤45min
Internal noise level ≤55dB
Humidity display range 10%-95%RH
Humidity accuracy ≤10%RH
Infant bed tilt angle +10º
Mattress size 67cm (L)×54cm(W)
Trough capacity 1200ml
Air filter 0.5um

Transport and Storage
Environment Temp:-10℃--+70℃
Environment Relative Humidity: ≤80% RH
Atmospheric Pressure: 500~1060Hpa